Skip to Content
Duct system DN 90
VENTIT FlowOne 160 – single-room heat recovery ventilation unit
VENTIT FlowOne 160 – single-room heat recovery ventilation unit
290,00 €
290,00 €
FANTINI COSMI ECOCOMFORT 160
FANTINI COSMI ECOCOMFORT 160
221,55 €
221,55 €

Premium plenum box with regulator 1xDN90 / Ø125 ID , 330 mm

VentPlan data

Premium angled plenum box 1xDN90 / internal Ø125 mm air-valve outlet, 330 mm, with integrated airflow regulation and orange locking clip.

45,00 € 45,00 €
≈

  • Brand - Ventit
  • Package contents
Expected to arrive on 6. November 2026
Ventit
Ventit

Ventit is a branch of Nest s.r.o., specializing in the production of air duct systems primarily for ventilation with heat recovery, along with other useful accessories. The majority of the manufacturing takes place directly in Slovakia.

Flexible shipping options Cost based on the address, weight, and order contents
B2B wholesale pricing Register as a partner for exclusive trade discounts

The description and analyses in this section apply to the Complete set with the Flow 125 anemostat.

VENTIT Premium Solution

Premium Box Set

Draught-free ventilation and easy balancing. It guides air along the ceiling and you set the airflow directly in the box. A set for DN90 duct with the Flow 125 anemostat.

✓
No draughtsThe air jet stays at the ceiling*
⚙
Easy balancingRegulator directly in the box
◎
Complete setFour parts in one package
◆
CFD analysisWe simulated the airflow in a room
VENTIT Premium Box Set

Why there are no draughts

You feel a draught when fast, cooler air lands on you. In a simulation with the anemostat in the centre of the room, the assembly prevented this as follows:*

01The air does not fallThe channels spread it sideways and the jet attaches to the ceiling (Coandă effect).
02It slows at the ceilingBetween 25 cm and 1 m from the anemostat, its speed falls about sixfold.
03It reaches room temperatureThe jet draws in room air: 21 °C becomes almost 23 °C within 1 m.
04It is slow in the roomAir speed is below 0.06 m/s in 95 % of the occupied zone.

What the airflow analysis showed

We calculated the airflow in the OpenFOAM CFD software for a 4.0 × 3.5 × 2.7 m room with a window and a door at a supply of 30 m³/h.*

Diagram of the jet at the ceiling: at 25 cm 1.1 m/s and 22.4 °C, at 50 cm 0.5 m/s and 22.7 °C, at 1 m 0.2 m/s and 22.9 °C
up to 5 cmfrom the ceiling is the reach of 0.20 m/s
below 0.06 m/sin 95 % of the occupied zone up to 1.8 m
up to 2.1 %predicted share of people dissatisfied with draught (DR, EN ISO 7730) in 95 % of the occupied zone
13 to 14 Papressure drop of the set with 1.1 m of DN90 duct at 30 m³/h
CFD simulation: section through the room with a jet at the ceiling
Section through the room: the fast jet stays right at the ceiling, and air in the blue area moves only slowly. The green band by the window and floor is cold air running down the glass, not the jet from the anemostat.
CFD simulation: air speed below the ceiling and at 1.1 m
On the same scale, there is a fast jet in all directions below the ceiling. At 1.1 m, the head height of a seated person, air moves at about 0.02 m/s on average.
CFD simulation: air paths in the room
Air paths over 120 s: the jet travels along the ceiling to the walls, falls along them and returns slowly through the room.

Where to place the anemostat

The centre of the room, on a flat ceiling without obstacles, gave the best result. Air was distributed most evenly by height there, and the least escaped through the gap under the door.*

After 4 minutesCentreCorner by windowBy the door
Air speed in 95 % of occupied zoneup to 0.058 m/sup to 0.073 m/sup to 0.056 m/s
DR in 95 % of occupied zone2.1 %4.4 %1.8 %
Fresh air at foot level4.15 %7.29 %2.82 %
Fresh air at seated head height4.35 %4.97 %6.93 %
Supplied air lost through the gap in 4.5 minabout 1.3 %about 2.8 %about 4.4 %

Easy balancing directly in the box

Section through the plenum box with the orange airflow regulator

The regulator is part of the box. You balance the airflow during installation and commissioning without closing the anemostat, which stays in its designed position.

Ideal for

Family houses
Apartments
New builds
Renovations
HVAC installers
Residential ventilation

Technical information

ParameterValue
Duct connection1×DN90, silicone seal and orange clip
Box outletinternal Ø125 mm
Box length330 mm
Regulationintegrated airflow regulator
Terminal elementFlow 125 anemostat
Pressure drop at 30 m³/h*about 13 to 14 Pa for the set with 1.1 m of DN90 duct, of which the anemostat and outlet about 7 to 8 Pa

FAQ

What does the Premium Box Set include?

Plenum box with regulator and clip, silicone duct seal, short flange and Flow 125 anemostat. DN90 duct is ordered separately.

Why does this set avoid draughts?

In the simulation, air travels along the ceiling, where it slows down and nearly reaches room temperature. Air speed is then below 0.06 m/s in 95 % of the occupied zone. Cold air running down a cold window still remains.

Where should the anemostat go?

As close to the centre of the room as possible, on a flat ceiling without obstacles. Best avoid a position next to the door.

Where is the airflow set?

With the regulator in the box, during installation and commissioning.

Are these values measured?

No, they are CFD simulation results for a supply of 30 m³/h. Physical airflow measurement is in progress, and we will quote noise only after measuring it.

No draughts. Regulation directly in the box.

The Premium Box Set combines the plenum box, seal, flange and Flow 125 anemostat into one set.

* CFD simulation results, not measurements. Supply 30 m³/h at 21 °C, regulator open; room 4.0 × 3.5 × 2.7 m at 23 °C, window glass 18 °C. Unless stated otherwise, the anemostat is in the centre of the room. Pressure drop: isothermal calculation 13.8 Pa, room calculation 12.9 Pa.

The transition box on its own

This section applies to the transition box, which is part of the set and is also sold separately.

VENTIT PREMIUM PLENUM BOX

Premium Plenum Box with Regulator

A premium angled plenum box for one DN90 duct with internal Ø125 mm air-valve outlet and integrated airflow regulation directly inside the box.

✓
1×DN90 connectionSecure duct connection with rubber seal.
◎
Internal Ø125 outletPrepared for air-valve connection.
↕
330 mm box lengthCompact angled construction.
◆
Integrated regulatorAirflow balancing directly inside the box.
Vývod Ø125
Regulátor
Vstup DN90
Premium Plenum Box with Regulator
Core idea

Cleaner airflow balancing, less visual compromise.

The integrated damper moves the regulation point away from the visible air valve and into the box.

Quiet balancingLower whistling risk on supply air valves.
Secure DN90 inletRubber seal with orange locking clip.
Smooth interiorFewer places for dirt to settle.
Installer friendlyMounting ears for ceiling, floor and screw fixing.

Why this design matters

Better acoustic comfortRegulation below the terminal element reduces the need to choke the air valve plate.
Faster professional installationRubber seal, locking clip and mounting ears simplify practical installation work.
Temporary protectionThe damper can help limit gravity airflow and protect ductwork from dust during construction.

Technical information

ParameterValue
Product typePremium angled plenum box with regulator
Duct connection1×DN90
Air-valve outletInternal Ø125 mm
Box length330 mm
RegulationIntegrated airflow damper
Duct securingRubber seal and orange locking clip
BrandVENTIT

FAQ

What is this plenum box used for?

It connects one DN90 duct to an internal Ø125 mm outlet for an air-valve collar and allows airflow balancing directly inside the box.

Is airflow regulation included?

Yes. The box includes an integrated damper for airflow regulation below the terminal element.

Why is regulation inside the box useful?

It reduces the need to close the visible valve plate, which can help lower the risk of whistling on supply air valves.

How is the DN90 duct secured?

The DN90 duct is inserted through a rubber seal and secured with an orange locking clip against pull-out.

Which accessories are available?

The concrete casting anchor set and drywall mounting flange are optional accessories designed for the 704010 plenum box.

Can the regulator be adjusted after installation?

The regulator is designed for airflow balancing during installation and commissioning, depending on the final system setup.

Premium airflow regulation inside the plenum box.

A professional DN90 plenum box with integrated airflow regulation, Ø125 mm outlet, rubber-seal duct connection and installer-friendly mounting details.

Package contents Complete set or Transition box only
Brand Ventit
0.0 /5

Based on 0 reviews

5
0
4
0
3
0
2
0
1
0
Customer Reviews

No reviews yet. Be the first to write a review!

VentPlan data

VentPlan model

Komponenta
PB 2xDN90/125 400mm + anemostat VentPlan diagram
Model
PB 2xDN90/125 400mm + anemostat
Výrobce
Ventit
Kategorie
plenums
2D model 3D model Materiály

3D náhled

OBJ + MTL
Komponenta · PB 2xDN90/125 400mm + anemostat
Načítám 3D model...
Derived from model name

Přechodový box pro napojení 2× DN90 na hlavní hrdlo Ø125, délka 400 mm. Dostupné: 2D diagram, 3D OBJ model, MTL materiály.

Typ komponentu přechodový box
Sekundární napojení 2× DN90
Hlavní hrdlo Ø125
Délka 400 mm
3D model OBJ + MTL

Frequently asked questions

Jaké hlavní hrdlo má tento přechodový box?
Má hlavní hrdlo Ø125.
Kolik napojení DN90 má tento komponent?
2 sekundární napojení DN90.
Je dostupný 3D model?
Ano, OBJ + MTL.
Je dostupný 2D technický diagram?
Ano.