Skip to Content
Duct system DN 90
Distribution box cone 4xDN90, throat 160
Distribution box cone 4xDN90, throat 160
70,62 €
70,62 €
Distribution box cone 8xDN90, throat 160
Distribution box cone 8xDN90, throat 160
174,00 €
174,00 €

Cone distributor 6xDN90, throat 160

VentPlan data

Cone distributor 6xDN90, throat 160. DN90 refers to the 90 mm outside duct diameter; the inside diameter is 75 mm.

124,00 € 124,00 €
≈

  • Brand - Ventit
  • Silencer
Ventit
Ventit

Ventit is a branch of Nest s.r.o., specializing in the production of air duct systems primarily for ventilation with heat recovery, along with other useful accessories. The majority of the manufacturing takes place directly in Slovakia.

Flexible shipping options Cost based on the address, weight, and order contents
B2B wholesale pricing Register as a partner for exclusive trade discounts

VENTIT cone distributor 6xDN90 with 160 mm throat

The VENTIT 6xDN90 distributor splits the air from the Ø160 mm main duct of a heat recovery unit into 6 DN90 ducts (90 mm outside, 75 mm inside diameter) leading to individual rooms. The outlets are arranged in 2 rows of 3. Internal channels guide the air smoothly to the outlets, so the distributor has a low pressure loss and splits the air evenly when the room ducts are connected.

Key benefits

  • Low pressure loss: 1.6 Pa at 180 m³/h (30 m³/h per outlet), 3.9 Pa at 300 m³/h.
  • Even airflow split: outlet deviation ±0.8 % with straight DN90 ducts connected to the rooms.
  • Quick duct connection: the DN90 ducts are held by orange pipe locks and sealed by rubber seals.
  • Ceiling mounting with adjustment: slotted holes allow ±5 mm shift if the wall plug is not exactly in place.
  • Crosstalk attenuation: speech from one room is 13.9 dB quieter in the neighbouring outlet (15.2 dB on average) – without acoustic foam, comparable to a sheet-metal box lined with 10 mm foam (12.8 dB).
  • Compact height: only 207 mm below the ceiling.

Computational flow simulation results

We verified the airflow in the distributor by computational flow simulation (physics-based calculation) at a supply of 180 m³/h. The even split applies with straight DN90 ducts connected to the rooms (typically approx. 10 m DN90 with a terminal valve per branch, about 20 Pa per branch). With very short branches the split may be less even.

Airflow streamlines in the 6xDN90 distributor – computational simulation

Airflow of individual outlets of the 6xDN90 distributor

Comparison of 6x, 8x and 12x DN90 distributors – pressure loss and airflow balance

Pressure loss of DN90 distributors versus airflow

Crosstalk attenuation – our distributor and a sheet-metal box with acoustic foam

Technical data

Number of outlets6 × DN90 (2 rows of 3)
Outlet ductsDN90 – Ø90 mm outside, Ø75 mm inside
Throat (unit connection)Ø160 mm
Recommended airflow30 m³/h per outlet (180 m³/h total)
Pressure loss1.6 Pa at 180 m³/h · 3.9 Pa at 300 m³/h
Outlet airflow deviation±0.8 % (with connected ducting)
Crosstalk attenuation13.9 dB neighbouring outlets, 15.2 dB average (speech, A-weighted)
Dimensions (W × H × L)364 × 207 × 270 mm (width incl. brackets, height below ceiling)
Weightapprox. 1.2 kg
Material and colour3D printed PLA, dark anthracite, orange pipe locks
Mountingceiling, slotted holes with ±5 mm adjustment (anchors not included)
Package contentsdistributor and 6 rubber DN90 duct seals

Installation

  1. Screw the distributor to the ceiling through the slotted holes in the brackets (anchors suitable for the ceiling).
  2. Fit the rubber seals on the DN90 ducts, push them into the outlets and secure them with the pipe locks.
  3. Connect the Ø160 mm throat to the main duct of the heat recovery unit.

Frequently asked questions

What airflow can the 6xDN90 distributor handle?

The recommended airflow is 30 m³/h per outlet, i.e. 180 m³/h in total, with a pressure loss of 1.6 Pa. Even at 50 m³/h per outlet (300 m³/h) the pressure loss is only 3.9 Pa.

Does the distributor split the air evenly to all rooms?

Yes – with straight DN90 ducts connected to the rooms (typically approx. 10 m with a terminal valve) the outlet airflow deviation is ±0.8 %. The exact airflow for each room is set with the terminal valves.

Which ducts fit the distributor?

The outlets fit DN90 ducts with 90 mm outside and 75 mm inside diameter, such as AirFlex DN90. The throat connects to the main duct of the unit.

How is the distributor installed?

On the ceiling through slotted holes with ±5 mm adjustment. It needs 207 mm below the ceiling. Ceiling anchors are not included, the rubber duct seals are.

Does sound travel between rooms through the distributor (crosstalk)?

The distributor attenuates sound between the outlets: speech from one room is 13.9 dB quieter in the neighbouring outlet and 15.2 dB on average. That is comparable to a sheet-metal box lined with 10 mm acoustic foam (12.8 dB), although our distributor has no foam. The ducts and terminal valves add further attenuation.

Can it be used for both supply and extract air?

Yes, the distributor is used in both the supply and the extract branch of heat recovery ventilation. The values shown apply to supply air.

Pressure loss, airflow split and crosstalk attenuation values come from computer simulation (physics-based calculation), not from measurement.

Brand Ventit
Silencer Without silencer
0.0 /5

Based on 0 reviews

5
0
4
0
3
0
2
0
1
0
Customer Reviews

No reviews yet. Be the first to write a review!

VentPlan data

VentPlan model

Component
DB 6xDN90 (OD90–ID75 / Ø160) VentPlan diagram
Model
DB 6xDN90 (OD90–ID75 / Ø160)
Number
712040
Manufacturer
Ventit
Category
dividers
2D model 3D model Materials

3D preview

OBJ + MTL
Component · DB 6xDN90 (OD90–ID75 / Ø160)
Loading 3D model...
Derived from model name

Distribution box for connecting 6× DN90 (OD90/ID75) to main port Ø160. Available: 2D diagram, 3D OBJ model, MTL materials.

Component type distribution box
Secondary connections 6× DN90
Outer / inner diameter OD90 / ID75
Main port Ø160
3D model OBJ + MTL

Frequently asked questions

What main port does this distribution box have?
It has a Ø160 main port.
How many DN90 connections does this component have?
6 secondary DN90 connections (OD90/ID75).
Is a 3D model available?
Yes, OBJ + MTL.
Is a 2D technical diagram available?
Yes.